Line 27: Line 27:


'''22 nodes, 44 cpus, 176 cores,''' split as follows due to differences between nodes ([https://public-api.grid5000.fr/stable/sites/luxembourg/clusters/granduc/nodes.json?pretty=1 json])
'''22 nodes, 44 cpus, 176 cores,''' split as follows due to differences between nodes ([https://public-api.grid5000.fr/stable/sites/luxembourg/clusters/granduc/nodes.json?pretty=1 json])
; granduc-[1-11,<wbr>13-15,<wbr>17-22] (20 nodes, 40 cpus, 160 cores)
; granduc-[1-6,<wbr>8-9,<wbr>14-15,<wbr>17-18,<wbr>20-22] (15 nodes, 30 cpus, 120 cores)
{|
{|
|-
|-
Line 43: Line 43:
|-
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  136&nbsp;GB HDD SAS ST9146802SS  (driver: mptsas)<br/>
|  136&nbsp;GB HDD SAS ST9146802SS  (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-phy0-lun-0)<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
|
* eth0/eno1, Ethernet (driver: bnx2), configured rate: 1&nbsp;Gbps  <br />
* eth1/eno2, Ethernet (driver: bnx2), configured rate: 1&nbsp;Gbps  <br />
* eth2/enp13s0f0, Ethernet (driver: ixgbe), configured rate: 10&nbsp;Gbps  - no KaVLAN <br />
* <span style="color:grey"> eth3/enp13s0f1, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment  </span><br/>
|-
|}
<hr style="height:10pt; visibility:hidden;" />
 
; granduc-[7] (1 node, 2 cpus, 8 cores)
{|
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Model:'''
| Dell PowerEdge 1950<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Date of arrival:'''
| 2011-12-01<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''CPU:'''
| Intel Xeon L5335 Clovertown  2.00GHz (2&nbsp;CPUs/node, 4&nbsp;cores/CPU)<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Memory:'''
| 16&nbsp;GB<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  136&nbsp;GB HDD SAS ST9146802SS  (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-0x5000c500078e9c6d-lun-0)<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
|
* eth0/eno1, Ethernet (driver: bnx2), configured rate: 1&nbsp;Gbps  <br />
* eth1/eno2, Ethernet (driver: bnx2), configured rate: 1&nbsp;Gbps  <br />
* eth2/enp13s0f0, Ethernet (driver: ixgbe), configured rate: 10&nbsp;Gbps  - no KaVLAN <br />
* <span style="color:grey"> eth3/enp13s0f1, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment  </span><br/>
|-
|}
<hr style="height:10pt; visibility:hidden;" />
 
; granduc-[10] (1 node, 2 cpus, 8 cores)
{|
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Model:'''
| Dell PowerEdge 1950<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Date of arrival:'''
| 2011-12-01<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''CPU:'''
| Intel Xeon L5335 Clovertown  2.00GHz (2&nbsp;CPUs/node, 4&nbsp;cores/CPU)<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Memory:'''
| 16&nbsp;GB<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  136&nbsp;GB HDD SAS ST9146802SS  (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-0x5000c5000ec6b751-lun-0)<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
|
* eth0/eno1, Ethernet (driver: bnx2), configured rate: 1&nbsp;Gbps  <br />
* eth1/eno2, Ethernet (driver: bnx2), configured rate: 1&nbsp;Gbps  <br />
* eth2/enp13s0f0, Ethernet (driver: ixgbe), configured rate: 10&nbsp;Gbps  - no KaVLAN <br />
* <span style="color:grey"> eth3/enp13s0f1, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment  </span><br/>
|-
|}
<hr style="height:10pt; visibility:hidden;" />
 
; granduc-[11] (1 node, 2 cpus, 8 cores)
{|
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Model:'''
| Dell PowerEdge 1950<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Date of arrival:'''
| 2011-12-01<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''CPU:'''
| Intel Xeon L5335 Clovertown  2.00GHz (2&nbsp;CPUs/node, 4&nbsp;cores/CPU)<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Memory:'''
| 16&nbsp;GB<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  136&nbsp;GB HDD SAS ST9146802SS  (driver: mptsas, path: node-was-not-available-to-retrieve-this-value)<br/>
|-
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
Line 71: Line 155:
|-
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  136&nbsp;GB HDD SAS ST9146802SS  (driver: mptsas)<br/>
|  136&nbsp;GB HDD SAS ST9146802SS  (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-phy0-lun-0)<br/>
|-
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
Line 79: Line 163:
* eth2/enp13s0f1, Ethernet (driver: ixgbe), configured rate: 10&nbsp;Gbps  - no KaVLAN <br />
* eth2/enp13s0f1, Ethernet (driver: ixgbe), configured rate: 10&nbsp;Gbps  - no KaVLAN <br />
* <span style="color:grey"> eth3/enp13s0f0, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment  </span><br/>
* <span style="color:grey"> eth3/enp13s0f0, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment  </span><br/>
|-
|}
<hr style="height:10pt; visibility:hidden;" />
; granduc-[13] (1 node, 2 cpus, 8 cores)
{|
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Model:'''
| Dell PowerEdge 1950<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Date of arrival:'''
| 2011-12-01<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''CPU:'''
| Intel Xeon L5335 Clovertown  2.00GHz (2&nbsp;CPUs/node, 4&nbsp;cores/CPU)<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Memory:'''
| 16&nbsp;GB<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  136&nbsp;GB HDD SAS ST9146802SS  (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-0x5000c5000ec32f35-lun-0)<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
|
* eth0/eno1, Ethernet (driver: bnx2), configured rate: 1&nbsp;Gbps  <br />
* eth1/eno2, Ethernet (driver: bnx2), configured rate: 1&nbsp;Gbps  <br />
* eth2/enp13s0f0, Ethernet (driver: ixgbe), configured rate: 10&nbsp;Gbps  - no KaVLAN <br />
* <span style="color:grey"> eth3/enp13s0f1, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment  </span><br/>
|-
|}
<hr style="height:10pt; visibility:hidden;" />
; granduc-[19] (1 node, 2 cpus, 8 cores)
{|
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Model:'''
| Dell PowerEdge 1950<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Date of arrival:'''
| 2011-12-01<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''CPU:'''
| Intel Xeon L5335 Clovertown  2.00GHz (2&nbsp;CPUs/node, 4&nbsp;cores/CPU)<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Memory:'''
| 16&nbsp;GB<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  136&nbsp;GB HDD SAS ST9146802SS  (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-0x5000c500078e9079-lun-0)<br/>
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
|
* eth0/eno1, Ethernet (driver: bnx2), configured rate: 1&nbsp;Gbps  <br />
* eth1/eno2, Ethernet (driver: bnx2), configured rate: 1&nbsp;Gbps  <br />
* eth2/enp13s0f0, Ethernet (driver: ixgbe), configured rate: 10&nbsp;Gbps  - no KaVLAN <br />
* <span style="color:grey"> eth3/enp13s0f1, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment  </span><br/>
|-
|-
|}
|}
Line 100: Line 240:
|-
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  232&nbsp;GB HDD SATA ST9250610NS  (driver: ahci)<br/>
|  232&nbsp;GB HDD SATA ST9250610NS  (driver: ahci, path: /dev/disk/by-path/pci-0000:00:1f.2-ata-1)<br/>
|-
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
Line 107: Line 247:
* eth1/eno2, Ethernet (driver: bnx2x), configured rate: 10&nbsp;Gbps  <br/>
* eth1/eno2, Ethernet (driver: bnx2x), configured rate: 10&nbsp;Gbps  <br/>
|-
|-
|}''<small>Generated from the Grid5000 APIs on 2018-04-18</small>''
|}''<small>Generated from the Grid5000 APIs on 2018-05-08</small>''

Revision as of 15:55, 8 May 2018


Summary

Cluster Queue Date of arrival Nodes CPU Cores Memory Storage Network
granduc default 2011-12-01 22 2 x Intel Xeon L5335 4 cores/CPU 16 GB 136 GB HDD 2 x 1 Gbps + 10 Gbps 
petitprince default 2013-09-10 16 2 x Intel Xeon E5-2630L 6 cores/CPU 32 GB 232 GB HDD 2 x 10 Gbps 

Cluster details

granduc

22 nodes, 44 cpus, 176 cores, split as follows due to differences between nodes (json)

granduc-[1-6,8-9,14-15,17-18,20-22] (15 nodes, 30 cpus, 120 cores)
Model: Dell PowerEdge 1950
Date of arrival: 2011-12-01
CPU: Intel Xeon L5335 Clovertown 2.00GHz (2 CPUs/node, 4 cores/CPU)
Memory: 16 GB
Storage: 136 GB HDD SAS ST9146802SS (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-phy0-lun-0)
Network:
  • eth0/eno1, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/eno2, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth2/enp13s0f0, Ethernet (driver: ixgbe), configured rate: 10 Gbps - no KaVLAN
  • eth3/enp13s0f1, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment

granduc-[7] (1 node, 2 cpus, 8 cores)
Model: Dell PowerEdge 1950
Date of arrival: 2011-12-01
CPU: Intel Xeon L5335 Clovertown 2.00GHz (2 CPUs/node, 4 cores/CPU)
Memory: 16 GB
Storage: 136 GB HDD SAS ST9146802SS (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-0x5000c500078e9c6d-lun-0)
Network:
  • eth0/eno1, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/eno2, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth2/enp13s0f0, Ethernet (driver: ixgbe), configured rate: 10 Gbps - no KaVLAN
  • eth3/enp13s0f1, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment

granduc-[10] (1 node, 2 cpus, 8 cores)
Model: Dell PowerEdge 1950
Date of arrival: 2011-12-01
CPU: Intel Xeon L5335 Clovertown 2.00GHz (2 CPUs/node, 4 cores/CPU)
Memory: 16 GB
Storage: 136 GB HDD SAS ST9146802SS (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-0x5000c5000ec6b751-lun-0)
Network:
  • eth0/eno1, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/eno2, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth2/enp13s0f0, Ethernet (driver: ixgbe), configured rate: 10 Gbps - no KaVLAN
  • eth3/enp13s0f1, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment

granduc-[11] (1 node, 2 cpus, 8 cores)
Model: Dell PowerEdge 1950
Date of arrival: 2011-12-01
CPU: Intel Xeon L5335 Clovertown 2.00GHz (2 CPUs/node, 4 cores/CPU)
Memory: 16 GB
Storage: 136 GB HDD SAS ST9146802SS (driver: mptsas, path: node-was-not-available-to-retrieve-this-value)
Network:
  • eth0/eno1, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/eno2, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth2/enp13s0f0, Ethernet (driver: ixgbe), configured rate: 10 Gbps - no KaVLAN
  • eth3/enp13s0f1, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment

granduc-[12,16] (2 nodes, 4 cpus, 16 cores)
Model: Dell PowerEdge 1950
Date of arrival: 2011-12-01
CPU: Intel Xeon L5335 Clovertown 2.00GHz (2 CPUs/node, 4 cores/CPU)
Memory: 16 GB
Storage: 136 GB HDD SAS ST9146802SS (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-phy0-lun-0)
Network:
  • eth0/eno1, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/eno2, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth2/enp13s0f1, Ethernet (driver: ixgbe), configured rate: 10 Gbps - no KaVLAN
  • eth3/enp13s0f0, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment

granduc-[13] (1 node, 2 cpus, 8 cores)
Model: Dell PowerEdge 1950
Date of arrival: 2011-12-01
CPU: Intel Xeon L5335 Clovertown 2.00GHz (2 CPUs/node, 4 cores/CPU)
Memory: 16 GB
Storage: 136 GB HDD SAS ST9146802SS (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-0x5000c5000ec32f35-lun-0)
Network:
  • eth0/eno1, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/eno2, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth2/enp13s0f0, Ethernet (driver: ixgbe), configured rate: 10 Gbps - no KaVLAN
  • eth3/enp13s0f1, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment

granduc-[19] (1 node, 2 cpus, 8 cores)
Model: Dell PowerEdge 1950
Date of arrival: 2011-12-01
CPU: Intel Xeon L5335 Clovertown 2.00GHz (2 CPUs/node, 4 cores/CPU)
Memory: 16 GB
Storage: 136 GB HDD SAS ST9146802SS (driver: mptsas, path: /dev/disk/by-path/pci-0000:02:08.0-sas-0x5000c500078e9079-lun-0)
Network:
  • eth0/eno1, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/eno2, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth2/enp13s0f0, Ethernet (driver: ixgbe), configured rate: 10 Gbps - no KaVLAN
  • eth3/enp13s0f1, Ethernet (driver: ixgbe), configured rate: n/c - unavailable for experiment

petitprince

16 nodes, 32 cpus, 192 cores (json)

Model: Dell PowerEdge M620
Date of arrival: 2013-09-10
CPU: Intel Xeon E5-2630L Sandy Bridge 2.00GHz (2 CPUs/node, 6 cores/CPU)
Memory: 32 GB
Storage: 232 GB HDD SATA ST9250610NS (driver: ahci, path: /dev/disk/by-path/pci-0000:00:1f.2-ata-1)
Network:
  • eth0/eno1, Ethernet (driver: bnx2x), configured rate: 10 Gbps
  • eth1/eno2, Ethernet (driver: bnx2x), configured rate: 10 Gbps

Generated from the Grid5000 APIs on 2018-05-08