See also: Network topology for Rennes
Summary
- 4 clusters
- 108 nodes
- 1820 CPU cores
- 6 GPUs
- 14.25 TiB RAM
- 33 SSDs and 314 HDDs on nodes (total: 199.6 TB)
- 67.4 TFLOPS (excluding GPUs)
Clusters
Cluster
|
Access Condition
|
Date of arrival
|
Nodes
|
CPU
|
Memory
|
Storage
|
Network
|
Accelerators
|
#
|
Name
|
Cores
|
Architecture
|
abacus25 |
production queue |
2023-06-05 |
2 |
2 |
AMD EPYC 7413 |
24 cores/CPU |
x86_64 |
512 GiB |
960 GB SSD + 2 x 960 GB SSD |
10 Gbps (SR‑IOV) |
3 x Nvidia A40 (45 GiB)
|
paranoia |
production queue |
2014-02-21 |
7 |
2 |
Intel Xeon E5-2660 v2 |
10 cores/CPU |
x86_64 |
128 GiB |
600 GB HDD + 4 x 600 GB HDD |
1 Gbps (SR‑IOV) + 2 x 10 Gbps (SR‑IOV) |
|
parasilo |
|
2015-01-13 |
27 |
2 |
Intel Xeon E5-2630 v3 |
8 cores/CPU |
x86_64 |
128 GiB |
600 GB HDD + 4 x 600 GB HDD* + 200 GB SSD* |
2 x 10 Gbps (SR‑IOV) |
|
paravance |
|
2015-01-13 |
72 |
2 |
Intel Xeon E5-2630 v3 |
8 cores/CPU |
x86_64 |
128 GiB |
600 GB HDD + 600 GB HDD |
2 x 10 Gbps (SR‑IOV) |
|
*: disk is reservable
**: crossed GPUs are not supported by Grid'5000 default environments
27 nodes, 54 cpus, 432 cores, split as follows due to differences between nodes (json)
Reservation example:
|
frennes :
|
oarsub -p parasilo -I
|
- parasilo-[1-5,7-12,14-15,17-24,26-28] (24 nodes, 48 cpus, 384 cores)
Model:
|
Dell PowerEdge R630
|
Date of arrival:
|
2015-01-13
|
CPU:
|
Intel Xeon E5-2630 v3 (Haswell, 2.40GHz, 2 CPUs/node, 8 cores/CPU)
|
Memory:
|
128 GiB
|
Storage:
|
- disk0, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk0 , by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:0:0 ) (primary disk)
- disk1, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk1 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:1:0 ) (reservable)
- disk2, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk2 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:2:0 ) (reservable)
- disk3, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk3 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:3:0 ) (reservable)
- disk4, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk4 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:4:0 ) (reservable)
- disk5, 200 GB SSD SAS Toshiba PX02SSF020 (dev:
/dev/disk5 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:5:0 ) (reservable)
|
Network:
|
- eth0/eno1, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled
- eth1/eno2, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled (multi NICs example)
- eth2/eno3, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
- eth3/eno4, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
|
- parasilo-6 (1 node, 2 cpus, 16 cores)
Model:
|
Dell PowerEdge R630
|
Date of arrival:
|
2015-01-13
|
CPU:
|
Intel Xeon E5-2630 v3 (Haswell, 2.40GHz, 2 CPUs/node, 8 cores/CPU)
|
Memory:
|
128 GiB
|
Storage:
|
- disk0, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk0 , by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:0:0 ) (primary disk)
- disk1, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk1 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:1:0 ) (reservable)
- disk2, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk2 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:2:0 ) (reservable)
- disk3, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk3 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:3:0 ) (reservable)
- disk4, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk4 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:4:0 ) (reservable)
- disk5, 200 GB SSD SAS Toshiba PX04SHB020 (dev:
/dev/disk5 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:5:0 ) (reservable)
|
Network:
|
- eth0/eno1, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled
- eth1/eno2, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled (multi NICs example)
- eth2/eno3, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
- eth3/eno4, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
|
- parasilo-13 (1 node, 2 cpus, 16 cores)
Model:
|
Dell PowerEdge R630
|
Date of arrival:
|
2015-01-13
|
CPU:
|
Intel Xeon E5-2630 v3 (Haswell, 2.40GHz, 2 CPUs/node, 8 cores/CPU)
|
Memory:
|
128 GiB
|
Storage:
|
- disk0, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk0 , by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:0:0 ) (primary disk)
- disk1, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk1 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:1:0 ) (reservable)
- disk2, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk2 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:2:0 ) (reservable)
- disk3, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk3 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:3:0 ) (reservable)
- disk4, 600 GB HDD SAS Toshiba AL15SEB060NY (dev:
/dev/disk4 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:4:0 ) (reservable)
- disk5, 200 GB SSD SAS Toshiba PX02SSF020 (dev:
/dev/disk5 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:5:0 ) (reservable)
|
Network:
|
- eth0/eno1, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled
- eth1/eno2, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled (multi NICs example)
- eth2/eno3, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
- eth3/eno4, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
|
- parasilo-25 (1 node, 2 cpus, 16 cores)
Model:
|
Dell PowerEdge R630
|
Date of arrival:
|
2015-01-13
|
CPU:
|
Intel Xeon E5-2630 v3 (Haswell, 2.40GHz, 2 CPUs/node, 8 cores/CPU)
|
Memory:
|
128 GiB
|
Storage:
|
- disk0, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk0 , by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:0:0 ) (primary disk)
- disk1, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk1 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:1:0 ) (reservable)
- disk2, 600 GB HDD SAS Seagate ST600MP0005 (dev:
/dev/disk2 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:2:0 ) (reservable)
- disk3, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk3 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:3:0 ) (reservable)
- disk4, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk4 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:4:0 ) (reservable)
- disk5, 200 GB SSD SAS Toshiba PX02SSF020 (dev:
/dev/disk5 *, by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:5:0 ) (reservable)
|
Network:
|
- eth0/eno1, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled
- eth1/eno2, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled (multi NICs example)
- eth2/eno3, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
- eth3/eno4, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
|
72 nodes, 144 cpus, 1152 cores (json)
Reservation example:
|
frennes :
|
oarsub -p paravance -I
|
Model:
|
Dell PowerEdge R630
|
Date of arrival:
|
2015-01-13
|
CPU:
|
Intel Xeon E5-2630 v3 (Haswell, 2.40GHz, 2 CPUs/node, 8 cores/CPU)
|
Memory:
|
128 GiB
|
Storage:
|
- disk0, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk0 , by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:0:0 ) (primary disk)
- disk1, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk1 , by-path: /dev/disk/by-path/pci-0000:03:00.0-scsi-0:0:1:0 )
|
Network:
|
- eth0/eno1, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled
- eth1/eno2, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled (multi NICs example)
- eth2/eno3, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
- eth3/eno4, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
|
2 nodes, 4 cpus, 96 cores (json)
Reservation example:
|
frennes :
|
oarsub -q production -p abacus25 -I
|
Max walltime per nodes:
- abacus25-1: 24h
- abacus25-2: 168h
Access condition:
|
production queue
|
Model:
|
HPE ProLiant DL385 Gen10+ v2
|
Date of arrival:
|
2023-06-05
|
CPU:
|
AMD EPYC 7413 (Zen 3, 2 CPUs/node, 24 cores/CPU)
|
Memory:
|
512 GiB
|
Storage:
|
- disk0, 960 GB SSD SAS HPE MO000960RXKRC (dev:
/dev/disk0 , by-path: /dev/disk/by-path/pci-0000:64:00.0-scsi-0:2:1:0 ) (primary disk)
- disk1, 960 GB SSD SATA HP VK000960GZCNF (dev:
/dev/disk1 , by-path: /dev/disk/by-path/pci-0000:64:00.0-scsi-0:2:2:0 )
- disk2, 960 GB SSD SATA HP VK000960GZCNF (dev:
/dev/disk2 , by-path: /dev/disk/by-path/pci-0000:64:00.0-scsi-0:2:3:0 )
|
Network:
|
- eth0/ens10f0, Ethernet, configured rate: 10 Gbps, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e, SR-IOV enabled - no KaVLAN
- eth1/ens10f1, Ethernet, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e - unavailable for experiment
|
GPU:
|
3 x Nvidia A40 (45 GiB) Compute capability: 8.6
|
7 nodes, 14 cpus, 140 cores, split as follows due to differences between nodes (json)
Reservation example:
|
frennes :
|
oarsub -q production -p paranoia -I
|
Max walltime per nodes:
- paranoia-[1-4]: 12h
- paranoia-[5-7]: 168h
- paranoia-[1-2,5,7] (4 nodes, 8 cpus, 80 cores)
Access condition:
|
production queue
|
Model:
|
Dell PowerEdge C6220 II
|
Date of arrival:
|
2014-02-21
|
CPU:
|
Intel Xeon E5-2660 v2 (Sandy Bridge, 2.20GHz, 2 CPUs/node, 10 cores/CPU)
|
Memory:
|
128 GiB
|
Storage:
|
- disk0, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk0 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy0-lun-0 ) (primary disk)
- disk1, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk1 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy1-lun-0 )
- disk2, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk2 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy2-lun-0 )
- disk3, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk3 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy3-lun-0 )
- disk4, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk4 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy4-lun-0 )
|
Network:
|
- eth0/enp3s0f0, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled
- eth1/enp3s0f1, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled (multi NICs example)
- eth2/eno1, Ethernet, configured rate: 1 Gbps, model: Intel I350 Gigabit Network Connection, driver: igb, SR-IOV enabled (multi NICs example)
- eth3/eno2, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
|
- paranoia-3 (1 node, 2 cpus, 20 cores)
Access condition:
|
production queue
|
Model:
|
Dell PowerEdge C6220 II
|
Date of arrival:
|
2014-02-21
|
CPU:
|
Intel Xeon E5-2660 v2 (Sandy Bridge, 2.20GHz, 2 CPUs/node, 10 cores/CPU)
|
Memory:
|
128 GiB
|
Storage:
|
- disk0, 600 GB HDD SAS Western Digital WD6002BKTG (dev:
/dev/disk0 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy0-lun-0 ) (primary disk)
- disk1, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk1 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy1-lun-0 )
- disk2, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk2 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy2-lun-0 )
- disk3, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk3 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy3-lun-0 )
- disk4, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk4 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy4-lun-0 )
|
Network:
|
- eth0/enp3s0f0, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled
- eth1/enp3s0f1, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled (multi NICs example)
- eth2/eno1, Ethernet, configured rate: 1 Gbps, model: Intel I350 Gigabit Network Connection, driver: igb, SR-IOV enabled (multi NICs example)
- eth3/eno2, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
|
- paranoia-4 (1 node, 2 cpus, 20 cores)
Access condition:
|
production queue
|
Model:
|
Dell PowerEdge C6220 II
|
Date of arrival:
|
2014-02-21
|
CPU:
|
Intel Xeon E5-2660 v2 (Sandy Bridge, 2.20GHz, 2 CPUs/node, 10 cores/CPU)
|
Memory:
|
128 GiB
|
Storage:
|
- disk0, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk0 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy0-lun-0 ) (primary disk)
- disk1, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk1 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy1-lun-0 )
- disk2, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk2 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy2-lun-0 )
- disk3, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk3 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy3-lun-0 )
- disk4, 600 GB HDD SAS Western Digital WD6002BKTG (dev:
/dev/disk4 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy4-lun-0 )
|
Network:
|
- eth0/enp3s0f0, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled
- eth1/enp3s0f1, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled (multi NICs example)
- eth2/eno1, Ethernet, configured rate: 1 Gbps, model: Intel I350 Gigabit Network Connection, driver: igb, SR-IOV enabled (multi NICs example)
- eth3/eno2, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
|
- paranoia-8 (1 node, 2 cpus, 20 cores)
Access condition:
|
production queue
|
Model:
|
Dell PowerEdge C6220 II
|
Date of arrival:
|
2014-02-21
|
CPU:
|
Intel Xeon E5-2660 v2 (Sandy Bridge, 2.20GHz, 2 CPUs/node, 10 cores/CPU)
|
Memory:
|
128 GiB
|
Storage:
|
- disk0, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk0 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy0-lun-0 ) (primary disk)
- disk1, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk1 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy1-lun-0 )
- disk2, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk2 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy2-lun-0 )
- disk3, 600 GB HDD SAS Seagate ST600MM0006 (dev:
/dev/disk3 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy3-lun-0 )
- disk4, 600 GB HDD SAS Western Digital WD6001BKHG (dev:
/dev/disk4 , by-path: /dev/disk/by-path/pci-0000:82:00.0-sas-phy4-lun-0 )
|
Network:
|
- eth0/enp3s0f0, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled
- eth1/enp3s0f1, Ethernet, configured rate: 10 Gbps, model: Intel 82599ES 10-Gigabit SFI/SFP+ Network Connection, driver: ixgbe, SR-IOV enabled (multi NICs example)
- eth2/eno1, Ethernet, configured rate: 1 Gbps, model: Intel I350 Gigabit Network Connection, driver: igb, SR-IOV enabled (multi NICs example)
- eth3/eno2, Ethernet, model: Intel I350 Gigabit Network Connection, driver: igb - unavailable for experiment
|
Last generated from the Grid'5000 Reference API on 2023-06-28 (commit 0bf887b857)