Grenoble:Hardware: Difference between revisions

From Grid5000
Jump to navigation Jump to search
No edit summary
No edit summary
(4 intermediate revisions by 2 users not shown)
Line 3: Line 3:
{{Portal|User}}
{{Portal|User}}
<div class="sitelink">Hardware: [[Hardware|Global]] | [[Grenoble:Hardware|Grenoble]] | [[Lille:Hardware|Lille]] | [[Luxembourg:Hardware|Luxembourg]] | [[Lyon:Hardware|Lyon]] | [[Nancy:Hardware|Nancy]] | [[Nantes:Hardware|Nantes]] | [[Rennes:Hardware|Rennes]] | [[Sophia:Hardware|Sophia]]</div>
<div class="sitelink">Hardware: [[Hardware|Global]] | [[Grenoble:Hardware|Grenoble]] | [[Lille:Hardware|Lille]] | [[Luxembourg:Hardware|Luxembourg]] | [[Lyon:Hardware|Lyon]] | [[Nancy:Hardware|Nancy]] | [[Nantes:Hardware|Nantes]] | [[Rennes:Hardware|Rennes]] | [[Sophia:Hardware|Sophia]]</div>
'''See also:''' [[Grenoble:Network|Network topology for Grenoble]]


= Summary =
= Summary =
Line 29: Line 30:
|}
|}
''*: disk is [[Disk_reservation|reservable]]''
''*: disk is [[Disk_reservation|reservable]]''
= Network topology =
See [[Grenoble:Network]]
= Clusters in default queue =
= Clusters in default queue =


Line 57: Line 56:
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  
|  
* 240&nbsp;GB SSD SATA Samsung MZ7KM240HMHQ0D3 (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:00:11.5-ata-3)  (primary disk)<br />
* disk0, 240&nbsp;GB SSD SATA Samsung MZ7KM240HMHQ0D3 (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:00:11.5-ata-3)  (primary disk)<br />
* 480&nbsp;GB SSD SATA Samsung MZ7KM480HMHQ0D3 (dev: /dev/sdb, by-path: /dev/disk/by-path/pci-0000:00:11.5-ata-4)  <br />
* disk1, 480&nbsp;GB SSD SATA Samsung MZ7KM480HMHQ0D3 (dev: /dev/sdb, by-path: /dev/disk/by-path/pci-0000:00:11.5-ata-4)  <br />
* 4.0&nbsp;TB HDD SATA Seagate ST4000NM0265-2DC (dev: /dev/sdc, by-path: /dev/disk/by-path/pci-0000:00:11.5-ata-5)  <br/>
* disk2, 4.0&nbsp;TB HDD SATA Seagate ST4000NM0265-2DC (dev: /dev/sdc, by-path: /dev/disk/by-path/pci-0000:00:11.5-ata-5)  <br/>
|-
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
Line 96: Line 95:
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  
|  
* 1.0&nbsp;TB HDD SATA Seagate ST1000NX0313 (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0009:04:00.0-ata-1)  (primary disk)<br />
* disk0, 1.0&nbsp;TB HDD SATA Seagate ST1000NX0313 (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0009:04:00.0-ata-1)  (primary disk)<br />
* 1.0&nbsp;TB HDD SATA Seagate ST1000NX0313 (dev: /dev/sdb, by-path: /dev/disk/by-path/pci-0009:04:00.0-ata-2)  <br/>
* disk1, 1.0&nbsp;TB HDD SATA Seagate ST1000NX0313 (dev: /dev/sdb, by-path: /dev/disk/by-path/pci-0009:04:00.0-ata-2)  <br/>
|-
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
Line 142: Line 141:
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  
|  
* 480&nbsp;GB SSD SATA Micron MTFDDAK480TDN (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0)  (primary disk)<br />
* disk0, 480&nbsp;GB SSD SATA Micron MTFDDAK480TDN (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0)  (primary disk)<br />
* 1.6&nbsp;TB SSD NVME Dell Samsung PM1735 (dev: /dev/nvme0n1, by-path: /dev/disk/by-path/pci-0000:d8:00.0-nvme-1)  <br/>
* disk1, 1.6&nbsp;TB SSD NVME Dell Samsung PM1735 (dev: /dev/nvme0n1, by-path: /dev/disk/by-path/pci-0000:d8:00.0-nvme-1)  <br/>
|-
|-
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Network:'''
Line 181: Line 180:
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  
|  
* 480&nbsp;GB SSD SATA Intel SSDSC2KG480G7R (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0)  (primary disk)<br />
* disk0, 480&nbsp;GB SSD SATA Intel SSDSC2KG480G7R (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0)  (primary disk)<br />
* 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdb*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:1:0) [[Disk_reservation|(reservable)]] <br />
* disk1, 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdb*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:1:0) [[Disk_reservation|(reservable)]] <br />
* 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdc*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:2:0) [[Disk_reservation|(reservable)]] <br />
* disk2, 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdc*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:2:0) [[Disk_reservation|(reservable)]] <br />
* 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdd*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:3:0) [[Disk_reservation|(reservable)]] <br />
* disk3, 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdd*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:3:0) [[Disk_reservation|(reservable)]] <br />
* 1.6&nbsp;TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme0n1, by-path: /dev/disk/by-path/pci-0000:59:00.0-nvme-1)  <br />
* disk4, 1.6&nbsp;TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme0n1, by-path: /dev/disk/by-path/pci-0000:59:00.0-nvme-1)  <br />
* 1.6&nbsp;TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme1n1, by-path: /dev/disk/by-path/pci-0000:6d:00.0-nvme-1)  <br />  
* disk5, 1.6&nbsp;TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme1n1, by-path: /dev/disk/by-path/pci-0000:6d:00.0-nvme-1)  <br />  
''*: the disk block device name /dev/sd? may vary in deployed environments, prefer referring to the by-path identifier''<br/>
''*: the disk block device name /dev/sd? may vary in deployed environments, prefer referring to the by-path identifier''<br/>
|-
|-
Line 220: Line 219:
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
| valign="top" style="background-color: #f9f9f9; padding: 0px 10px 0px 3px;" |'''Storage:'''
|  
|  
* 480&nbsp;GB SSD SATA Intel SSDSC2KG480G8R (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0)  (primary disk)<br />
* disk0, 480&nbsp;GB SSD SATA Intel SSDSC2KG480G8R (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0)  (primary disk)<br />
* 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdb*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:1:0) [[Disk_reservation|(reservable)]] <br />
* disk1, 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdb*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:1:0) [[Disk_reservation|(reservable)]] <br />
* 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdc*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:2:0) [[Disk_reservation|(reservable)]] <br />
* disk2, 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdc*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:2:0) [[Disk_reservation|(reservable)]] <br />
* 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdd*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:3:0) [[Disk_reservation|(reservable)]] <br />
* disk3, 2.0&nbsp;TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdd*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:3:0) [[Disk_reservation|(reservable)]] <br />
* 1.6&nbsp;TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme0n1, by-path: /dev/disk/by-path/pci-0000:59:00.0-nvme-1)  <br />
* disk4, 1.6&nbsp;TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme0n1, by-path: /dev/disk/by-path/pci-0000:59:00.0-nvme-1)  <br />
* 1.6&nbsp;TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme1n1, by-path: /dev/disk/by-path/pci-0000:6d:00.0-nvme-1)  <br />  
* disk5, 1.6&nbsp;TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme1n1, by-path: /dev/disk/by-path/pci-0000:6d:00.0-nvme-1)  <br />  
''*: the disk block device name /dev/sd? may vary in deployed environments, prefer referring to the by-path identifier''<br/>
''*: the disk block device name /dev/sd? may vary in deployed environments, prefer referring to the by-path identifier''<br/>
|-
|-
Line 236: Line 235:
* ib0, Omni-Path, configured rate: 100&nbsp;Gbps, model: Intel Omni-Path HFI Silicon 100 Series [discrete], driver: hfi1<br/>
* ib0, Omni-Path, configured rate: 100&nbsp;Gbps, model: Intel Omni-Path HFI Silicon 100 Series [discrete], driver: hfi1<br/>
|-
|-
|}''<small>Last generated from the Grid'5000 Reference API on 2021-04-21 ([https://github.com/grid5000/reference-repository/commit/bdd1cad6aa commit bdd1cad6aa])</small>''
|}''<small>Last generated from the Grid'5000 Reference API on 2021-07-16 ([https://github.com/grid5000/reference-repository/commit/5c644032ae commit 5c644032ae])</small>''

Revision as of 14:59, 16 July 2021

See also: Network topology for Grenoble

Summary

4 clusters, 52 nodes, 1648 cores, 98.4 TFLOPS

Cluster Access Condition Date of arrival Nodes CPU Cores Memory Storage Network Accelerators
dahu 2018-03-22 32 2 x Intel Xeon Gold 6130 16 cores/CPU 192 GiB 240 GB SSD + 480 GB SSD + 4.0 TB HDD 10 Gbps + 100 Gbps Omni-Path
drac exotic job type 2020-10-05 12 2 x POWER8NVL 1.0 10 cores/CPU 128 GiB 1 x 1.0 TB HDD + 1 x 1.0 TB HDD 10 Gbps + 2 x 100 Gbps InfiniBand 4 x Nvidia Tesla P100
troll exotic job type 2019-12-23 4 2 x Intel Xeon Gold 5218 16 cores/CPU 384 GiB + 1.5 TiB PMEM 480 GB SSD + 1.6 TB SSD 25 Gbps + 100 Gbps Omni-Path
yeti exotic job type 2018-01-16 4 4 x Intel Xeon Gold 6130 16 cores/CPU 768 GiB 480 GB SSD + 3 x 2.0 TB HDD* + 2 x 1.6 TB SSD 10 Gbps + 100 Gbps Omni-Path

*: disk is reservable

Clusters in default queue

dahu

32 nodes, 64 cpus, 1024 cores (json)

Reservation example:

Terminal.png fgrenoble:
oarsub -p "cluster='dahu'" -I
Model: Dell PowerEdge C6420
Date of arrival: 2018-03-22
CPU: Intel Xeon Gold 6130 (Skylake, 2.10GHz, 2 CPUs/node, 16 cores/CPU)
Memory: 192 GiB
Storage:
  • disk0, 240 GB SSD SATA Samsung MZ7KM240HMHQ0D3 (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:00:11.5-ata-3) (primary disk)
  • disk1, 480 GB SSD SATA Samsung MZ7KM480HMHQ0D3 (dev: /dev/sdb, by-path: /dev/disk/by-path/pci-0000:00:11.5-ata-4)
  • disk2, 4.0 TB HDD SATA Seagate ST4000NM0265-2DC (dev: /dev/sdc, by-path: /dev/disk/by-path/pci-0000:00:11.5-ata-5)
Network:
  • eth0/enp24s0f0, Ethernet, configured rate: 10 Gbps, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e
  • eth1/enp24s0f1, Ethernet, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e - unavailable for experiment
  • ib0, Omni-Path, configured rate: 100 Gbps, model: Intel Omni-Path HFI Silicon 100 Series [discrete], driver: hfi1

drac

12 nodes, 24 cpus, 240 cores (json)

Reservation example:

Terminal.png fgrenoble:
oarsub -t exotic -p "cluster='drac'" -I
Access condition: exotic job type
Model: IBM PowerNV S822LC (8335-GTB)
Date of arrival: 2020-10-05
CPU: POWER8NVL 1.0 (POWER8, 2 CPUs/node, 10 cores/CPU)
Memory: 128 GiB
Storage:
  • disk0, 1.0 TB HDD SATA Seagate ST1000NX0313 (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0009:04:00.0-ata-1) (primary disk)
  • disk1, 1.0 TB HDD SATA Seagate ST1000NX0313 (dev: /dev/sdb, by-path: /dev/disk/by-path/pci-0009:04:00.0-ata-2)
Network:
  • eth0/enP1p1s0f0, Ethernet, configured rate: 10 Gbps, model: Broadcom NetXtreme II BCM57800 1/10 Gigabit Ethernet, driver: bnx2x
  • eth1/enP1p1s0f1, Ethernet, model: Broadcom NetXtreme II BCM57800 1/10 Gigabit Ethernet, driver: bnx2x - unavailable for experiment
  • eth2/enP1p1s0f2, Ethernet, model: Broadcom NetXtreme II BCM57800 1/10 Gigabit Ethernet, driver: bnx2x - unavailable for experiment
  • eth3/enP1p1s0f3, Ethernet, model: Broadcom NetXtreme II BCM57800 1/10 Gigabit Ethernet, driver: bnx2x - unavailable for experiment
  • eth4/enP9p7s0f0, Ethernet, configured rate: 1 Gbps, model: Broadcom NetXtreme BCM5719 Gigabit Ethernet PCIe, driver: tg3 - unavailable for experiment
  • eth5/enP9p7s0f1, Ethernet, model: Broadcom NetXtreme BCM5719 Gigabit Ethernet PCIe, driver: tg3 - unavailable for experiment
  • ib0, InfiniBand, configured rate: 100 Gbps, model: Mellanox Technologies MT27700 Family [ConnectX-4], driver: mlx5_core
  • ib1, InfiniBand, configured rate: 100 Gbps, model: Mellanox Technologies MT27700 Family [ConnectX-4], driver: mlx5_core
GPU: 4 x Nvidia Tesla P100-SXM2-16GB

troll

4 nodes, 8 cpus, 128 cores (json)

Reservation example:

Terminal.png fgrenoble:
oarsub -t exotic -p "cluster='troll'" -I
Access condition: exotic job type
Model: Dell PowerEdge R640
Date of arrival: 2019-12-23
CPU: Intel Xeon Gold 5218 (Cascade Lake-SP, 2.30GHz, 2 CPUs/node, 16 cores/CPU)
Memory: 384 GiB + 1.5 TiB PMEM
Storage:
  • disk0, 480 GB SSD SATA Micron MTFDDAK480TDN (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0) (primary disk)
  • disk1, 1.6 TB SSD NVME Dell Samsung PM1735 (dev: /dev/nvme0n1, by-path: /dev/disk/by-path/pci-0000:d8:00.0-nvme-1)
Network:
  • eth0/eno1, Ethernet, configured rate: 25 Gbps, model: Mellanox Technologies MT27710 Family [ConnectX-4 Lx], driver: mlx5_core
  • eth1/eno2, Ethernet, model: Mellanox Technologies MT27710 Family [ConnectX-4 Lx], driver: mlx5_core - unavailable for experiment
  • ib0, Omni-Path, configured rate: 100 Gbps, model: Intel Omni-Path HFI Silicon 100 Series [discrete], driver: hfi1

yeti

4 nodes, 16 cpus, 256 cores, split as follows due to differences between nodes (json)

Reservation example:

Terminal.png fgrenoble:
oarsub -t exotic -p "cluster='yeti'" -I
yeti-[1-2,4] (3 nodes, 12 cpus, 192 cores)
Access condition: exotic job type
Model: Dell PowerEdge R940
Date of arrival: 2018-01-16
CPU: Intel Xeon Gold 6130 (Skylake, 2.10GHz, 4 CPUs/node, 16 cores/CPU)
Memory: 768 GiB
Storage:
  • disk0, 480 GB SSD SATA Intel SSDSC2KG480G7R (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0) (primary disk)
  • disk1, 2.0 TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdb*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:1:0) (reservable)
  • disk2, 2.0 TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdc*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:2:0) (reservable)
  • disk3, 2.0 TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdd*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:3:0) (reservable)
  • disk4, 1.6 TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme0n1, by-path: /dev/disk/by-path/pci-0000:59:00.0-nvme-1)
  • disk5, 1.6 TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme1n1, by-path: /dev/disk/by-path/pci-0000:6d:00.0-nvme-1)

*: the disk block device name /dev/sd? may vary in deployed environments, prefer referring to the by-path identifier

Network:
  • eth0/eno1, Ethernet, configured rate: 10 Gbps, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e
  • eth1/eno2, Ethernet, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e - unavailable for experiment
  • eth2/eno3, Ethernet, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e - unavailable for experiment
  • eth3/eno4, Ethernet, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e - unavailable for experiment
  • ib0, Omni-Path, configured rate: 100 Gbps, model: Intel Omni-Path HFI Silicon 100 Series [discrete], driver: hfi1

yeti-3 (1 node, 4 cpus, 64 cores)
Access condition: exotic job type
Model: Dell PowerEdge R940
Date of arrival: 2018-01-16
CPU: Intel Xeon Gold 6130 (Skylake, 2.10GHz, 4 CPUs/node, 16 cores/CPU)
Memory: 768 GiB
Storage:
  • disk0, 480 GB SSD SATA Intel SSDSC2KG480G8R (dev: /dev/sda, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:0:0) (primary disk)
  • disk1, 2.0 TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdb*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:1:0) (reservable)
  • disk2, 2.0 TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdc*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:2:0) (reservable)
  • disk3, 2.0 TB HDD SAS Seagate ST2000NX0463 (dev: /dev/sdd*, by-path: /dev/disk/by-path/pci-0000:18:00.0-scsi-0:0:3:0) (reservable)
  • disk4, 1.6 TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme0n1, by-path: /dev/disk/by-path/pci-0000:59:00.0-nvme-1)
  • disk5, 1.6 TB SSD NVME Dell Dell Express Flash NVMe PM1725 1.6TB AIC (dev: /dev/nvme1n1, by-path: /dev/disk/by-path/pci-0000:6d:00.0-nvme-1)

*: the disk block device name /dev/sd? may vary in deployed environments, prefer referring to the by-path identifier

Network:
  • eth0/eno1, Ethernet, configured rate: 10 Gbps, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e
  • eth1/eno2, Ethernet, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e - unavailable for experiment
  • eth2/eno3, Ethernet, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e - unavailable for experiment
  • eth3/eno4, Ethernet, model: Intel Ethernet Controller X710 for 10GbE SFP+, driver: i40e - unavailable for experiment
  • ib0, Omni-Path, configured rate: 100 Gbps, model: Intel Omni-Path HFI Silicon 100 Series [discrete], driver: hfi1

Last generated from the Grid'5000 Reference API on 2021-07-16 (commit 5c644032ae)