Topologie physique du réseau de calcul

IP networks in use

The following table shows the addresses used. You have to use routable addresses if your experiments are going to run between several sites.

Site network IP addresses netmask public routable was date of change comments
Lille computing 192.168.159.0 /24 (255.255.255.0) no yes
admin 192.168.160.0 /24 (255.255.255.0) no no
ipmi 192.168.161.0 /24 (255.255.255.0) no no
rsa 192.168.158.0 /24 (255.255.255.0) no no

Architecture actuelle :

Routage :

 1 chassis Cisco 6506 équipée dune carte Supervisor 720 Fabric MSFC3 PFC3B

Interconnexion Grid'5000 :

 Carte d'extention 4 ports 10 Gigabit Ethernet (Module XENPACK) sur le chassis Cisco 6506

Réseau de Calcul :

 3 Cartes de commutation 48 Ports 10/100/1000 + 3 cartes additionnelles DFC3A sur chassis 
Cisco 6506 (gigabit non bloquant)

Réseau d'administration :

 4 Switchs cisco 2960 (émulation d'un stack avec interconnexion full mesh)
 un lien 2Gb/s relie chaque chassis au 6506.

Réseau RSA :

 3 Switch Netgear 10/100PT

Réseau ipmi :

Réseau Myrinet :

  switch myrinet 128 ports

Lien 3 Gb/s vers serveur de fichiers sur le réseau d'admin

 sur le réseau d'administration

Accès externe :

 1 Switch Cisco 3750 24 Ports GE

Archi-reseau-lille.png